NEC Code Practice Tests Quiz Questions Answers 9
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading...
You must sign in or sign up to start the quiz.
You have to finish following quiz, to start this quiz:
Results
0 of 12 questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 points, (0)
Average score |
|
Your score |
|
Categories
- Not categorized 0%
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- Answered
- Review
-
Question 1 of 12
1. Question
1 pointsA general use ac snap switch is permitted as the motor disconnecting means for ac motors rated _____ or less and 300V
Correct
Please Refer: NEC Code 430.83(C)
Incorrect
Please Refer: NEC Code 430.83(C)
-
Question 2 of 12
2. Question
1 pointsFor hermetic refrigerant motor compressor, the ampere rating must be ______ of the nameplate rated load current or branch circuit selection current whichever is greater:
Correct
Please Refer: NEC Code 440.12(A)(1)
Incorrect
Please Refer: NEC Code 440.12(A)(1)
-
Question 3 of 12
3. Question
1 pointsIf the room air conditioner is the only load connected to the circuit, the marking rating of the air conditioner must not exceed ______ of the rating of the circuit overcurrent device:
Correct
Please Refer: NEC Code 440.62(B)
Incorrect
Please Refer: NEC Code 440.62(B)
-
Question 4 of 12
4. Question
1 pointsThe ampacity of the conductors from the generator winding to the line side of the generator overcurrent protection device must not be less than ______ of the nameplate rating of the generator:
Correct
Please Refer: NEC Code 445.13
Incorrect
Please Refer: NEC Code 445.13
-
Question 5 of 12
5. Question
1 pointsThe dwelling unit feeder / service neutral calculated load for household electric ranges, wall mounted ovens, or counter mounted cooking units can be calculated at _______ of the cooling equipment calculated load:
Correct
Please Refer: NEC Code 220.61(B)(1)
Incorrect
Please Refer: NEC Code 220.61(B)(1)
-
Question 6 of 12
6. Question
1 pointsOverhead conductors installed above a window is required to maintain 3 ft distance from the window:
Correct
Please Refer: NEC Code 225.19(D)(1) Exp
Incorrect
Please Refer: NEC Code 225.19(D)(1) Exp
-
Question 7 of 12
7. Question
1 pointsConductors are considered outside when encased or installed under not less thanĀ _____ of concrete:
Correct
Please Refer: NEC Code 230.6
Incorrect
Please Refer: NEC Code 230.6
-
Question 8 of 12
8. Question
1 pointsOverhead service conductors must maintain a vertical clearance not less than _____ above platforms, projections or surfaces from which they might be reached:
Correct
Please Refer: NEC Code 230.24(B)
Incorrect
Please Refer: NEC Code 230.24(B)
-
Question 9 of 12
9. Question
1 pointsUnderground service conductors must be smaller than ______ copper conductor:
Correct
Please Refer: NEC Code 230.31(B)
Incorrect
Please Refer: NEC Code 230.31(B)
-
Question 10 of 12
10. Question
1 pointsUnderground service conductors must have their location identified by a warning ribbon placed in the trench atleast _____ above the underground conductor installation:
Correct
Please Refer: NEC Code 300.5(D)(3)
Incorrect
Please Refer: NEC Code 300.5(D)(3)
-
Question 11 of 12
11. Question
1 pointsThe smallest conductor permitted for branch circuits for residential, commercial and industrial locations is _____ copper conductor:
Correct
Please Refer: NEC Code 310.106(A)
Incorrect
Please Refer: NEC Code 310.106(A)
-
Question 12 of 12
12. Question
1 pointsType AC Cable must be secured within _____ of every outlet box, junction box, cabinet or fittings at an interval not exceeding 4.5 feet:
Correct
Please Refer: NEC Code 330.30(B)
Incorrect
Please Refer: NEC Code 330.30(B)