Quiz-summary
0 of 15 questions completed
Questions:
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
Information
NEC Code Practice Tests Quiz Questions Answers 13
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading...
You must sign in or sign up to start the quiz.
You have to finish following quiz, to start this quiz:
Results
0 of 15 questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 points, (0)
Average score |
|
Your score |
|
Categories
- Not categorized 0%
-
Congrats, You Passed the Test
-
Sorry, You did not Pass
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- Answered
- Review
-
Question 1 of 15
1. Question
1 pointsType S fuses operate at not more than 125V and does not have ampere rating of:
Correct
Please Refer: NEC Code 240.53(A)
Incorrect
Please Refer: NEC Code 240.53(A)
-
Question 2 of 15
2. Question
1 pointsOvercurrent devices must not be located over the steps of the stairway:
Correct
Please Refer: NEC Code 240.24(F)
Incorrect
Please Refer: NEC Code 240.24(F)
-
Question 3 of 15
3. Question
1 pointsFeeder tap conductors upto 10 ft long are permitted without overcurrent protection at the tap location if the ampacity of the tap conductors must not be less than _______ the rating of the overcurrent device that protects the feeder:
Correct
Please Refer: NEC Code 240.21(1)(b)(4)
Incorrect
Please Refer: NEC Code 240.21(1)(b)(4)
-
Question 4 of 15
4. Question
1 pointsSingle pole AFCI or GFCI circuit breakers are not suitable for protecting multiwire branch circuits:
Correct
Incorrect
-
Question 5 of 15
5. Question
1 pointsFor installations consisting of a single branch circuit, the disconnecting means must have a rating not less than _____:
Correct
Please Refer: NEC Code 230.79(A)
Incorrect
Please Refer: NEC Code 230.79(A)
-
Question 6 of 15
6. Question
1 pointsIf the edge of the hole is less than 1 (1/4) in. from the edge, a _____ thick steel plate of sufficient length and width must be installed to protect the wiring method from the screws and nails:
Correct
Please Refer: NEC Code 300.4(A)(1)
Incorrect
Please Refer: NEC Code 300.4(A)(1)
-
Question 7 of 15
7. Question
1 pointsRaceways at the bottom of open bottom equipment, such as switchboards, motor control centers, and transformers are required to be mechanically secured to the equipment:
Correct
Please Refer: NEC Code 300.12 Exp-2
Incorrect
-
Question 8 of 15
8. Question
1 pointsAn enclosure can be used as a raceway if total area of the conductors at any cross section does not exceed ______ of the cross-sectional area of the space
Correct
Please Refer: NEC Code 312.8(1)
Incorrect
Please Refer: NEC Code 312.8(1)
-
Question 9 of 15
9. Question
1 pointsType AC Cable, must be secured within _____ of every outlet box, junction box, or fittings at an interval not exceeding 4.5 feet:
Correct
Please Refer: NEC Code 320.30(B)
Incorrect
Please Refer: NEC Code 320.30(B)
-
Question 10 of 15
10. Question
1 pointsMinimum trade size of Rigid Metal Conduit (RMC) must be ______:
Correct
Please Refer: NEC Code 344.20(B)
Incorrect
Please Refer: NEC Code 344.20(B)
-
Question 11 of 15
11. Question
1 pointsLuminaires must maintain a minimum clearance of ______ from surface mounted fluorescent lamps:
Correct
Please Refer: NEC Code 410.16(C)(2)
Incorrect
Please Refer: NEC Code 410.16(C)(2)
-
Question 12 of 15
12. Question
1 pointsNo part of chain or cord suspended luminaires or ceiling fans can be located within ____ horizontally from the top of the bathtub rim or shower stall threshold:
Correct
Please Refer: NEC Code 410.10(D)
Incorrect
Please Refer: NEC Code 410.10(D)
-
Question 13 of 15
13. Question
1 pointsIn a room it is observed that air conditioner is the only load on the circuit, then the marked rating of the air conditioner must not exceed _____ of the rating of the circuit overcurrent device:
Correct
Please Refer: NEC Code 440.62(B)
Incorrect
Please Refer: NEC Code 440.62(B)
-
Question 14 of 15
14. Question
1 pointsThe underground conductors that connects between the utility electric supply and the service point is ______
Correct
Please Refer: NEC Code 100
Incorrect
-
Question 15 of 15
15. Question
1 pointsA permanently connected surge protective device listed for installation between the utility transformer and the service equipment is _____ Surge Protective Device (SPD):
Correct
Please Refer: NEC Code 100
Incorrect