NEC Code Practice Tests Quiz Questions Answers 15
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading...
You must sign in or sign up to start the quiz.
You have to finish following quiz, to start this quiz:
Results
0 of 15 questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 points, (0)
Average score |
|
Your score |
|
Categories
- Not categorized 0%
-
Congrats, You Passed the Test
-
Sorry, You did not Pass
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- Answered
- Review
-
Question 1 of 15
1. Question
1 pointsOverhead conductor spans must maintain vertical clearance of _____ above residential property and driveways and those commercial areas not subject to truck traffic for 120V, 120/208V, and 480V circuits:
Correct
Please Refer: NEC Code 225.18(2)
Incorrect
Please Refer: NEC Code 225.18(2)
-
Question 2 of 15
2. Question
1 pointsOverhead conductors must maintain a clearance of ____ from the chimneys, radio and television antennas and other non building structures:
Correct
Please Refer: NEC Code 225.19(B)
Incorrect
Please Refer: NEC Code 225.19(B)
-
Question 3 of 15
3. Question
1 pointsAC systems less than ____ are not required to be grounded:
Correct
Please Refer: NEC Code 250.20(A)
Incorrect
Please Refer: NEC Code 250.20(A)
-
Question 4 of 15
4. Question
1 pointsEquipment can be located behind the door provided a _____ working space is achieved by closing the door:
Correct
Incorrect
-
Question 5 of 15
5. Question
1 pointsNonmetallic-sheathed cable (secured to the box) must be secured within _____ of every box, cabinet or fitting:
Correct
Please Refer: NEC Code 334.30
Incorrect
Please Refer: NEC Code 334.30
-
Question 6 of 15
6. Question
1 pointsThe maximum approved electrical trade size for RMC is _______:
Correct
Please Refer: NEC Code 344.20(B)
Incorrect
Please Refer: NEC Code 344.20(B)
-
Question 7 of 15
7. Question
1 pointsNo part of chain, cable or cord suspended luminaires can be located within _____ vertically from the top of the bathtub rim or shower stall threshold:
Correct
Please Refer: NEC Code 410.10(D)
Incorrect
Please Refer: NEC Code 410.10(D)
-
Question 8 of 15
8. Question
1 pointsA short circuit rating is not required on controllers rated less than ____ at 300V or less, if they are listed for use on general purpose branch circuits:
Correct
Please Refer: NEC Code 430.8 (Ex-4)
Incorrect
Please Refer: NEC Code 430.8 (Ex-4)
-
Question 9 of 15
9. Question
1 pointsA general use ac snap switch where the motor FLC rating is not more than _____ of the ampere rating of the switch:
Correct
Please Refer: NEC Code 430.83(C)(2)
Incorrect
Please Refer: NEC Code 430.83(C)(2)
-
Question 10 of 15
10. Question
1 pointsSnap switches rated ____ or less connected to aluminum wire must be marked CO/ALR:
Correct
Please Refer: NEC Code 404.14(C)
Incorrect
Please Refer: NEC Code 404.14(C)
-
Question 11 of 15
11. Question
1 pointsOverhead service conductors must maintain a vertical clearance not less than _____ above platforms, projections, or surfaces from which they ,might be reached:
Correct
Please Refer: NEC Code 230.9(B)
Incorrect
Please Refer: NEC Code 230.9(B)
-
Question 12 of 15
12. Question
1 pointsFor a feeder rated 100A through 400A, feeder conductors supplying a one family dwelling, or an individual dwelling unit in a two family or multifamily dwelling, can have an ampacity of _____ of the feeder rating, but only if the feeder supplies the entire load of the dwelling:
Correct
Please Refer: NEC Code 310.15(B)(7)(2)
Incorrect
Please Refer: NEC Code 310.15(B)(7)(2)
-
Question 13 of 15
13. Question
1 pointsType AC Cable can be unsupported where the cable is not more than ______ long at terminals where flexibility is necessary:
Correct
Please Refer: NEC Code 320.30(D)(2)
Incorrect
Please Refer: NEC Code 320.30(D)(2)
-
Question 14 of 15
14. Question
1 pointsType NM cable may be used in wet and damp locations:
Correct
Please Refer: NEC Code 334.12(B)(4)
Incorrect
Please Refer: NEC Code 334.12(B)(4)
-
Question 15 of 15
15. Question
1 pointsPVC conduit smaller than trade size ______ must not be used:
Correct
Please Refer: NEC Code 352.20(A)
Incorrect
Please Refer: NEC Code 352.20(A)