Information
NEC Code Practice Tests Quiz Questions Answers 17
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading...
You must sign in or sign up to start the quiz.
You have to finish following quiz, to start this quiz:
Results
0 of 15 questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 points, (0)
Average score |
|
Your score |
|
Categories
- Not categorized 0%
-
Congrats, You Passed the Test
-
Sorry, You did not Pass
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- Answered
- Review
-
Question 1 of 15
1. Question
1 pointsA disconnect is required for all the conductors that enter a building:
Correct
Please Refer: NEC Code 225.31
Incorrect
Please Refer: NEC Code 225.31
-
Question 2 of 15
2. Question
1 pointsThe _____ clearance of overhead conductors from the roof edge does not apply when the point of attachment is on the side of the building below the roof:
Correct
Please Refer: NEC Code 225.19(A)(Exp-4)
Incorrect
Please Refer: NEC Code 225.19(A)(Exp-4)
-
Question 3 of 15
3. Question
1 pointsIMC must generally be supported at intervals not exceeding _____:
Correct
Please Refer: NEC Code 342.30(B)(1)
Incorrect
Please Refer: NEC Code 342.30(B)(1)
-
Question 4 of 15
4. Question
1 pointsThe point of connection between serving utility and the premises wiring:
Correct
Please Refer: NEC Code 100
Incorrect
Please Refer: NEC Code 100
-
Question 5 of 15
5. Question
1 pointsA standard fuse will clear the fault in ________:
Correct
Please Refer: NEC Code 240.2
Incorrect
Please Refer: NEC Code 240.2
-
Question 6 of 15
6. Question
1 pointsThe overcurrent protection for 10 AWG copper conductor must not exceed ______:
Correct
Please Refer: NEC Code 240.4(D)(7)
Incorrect
Please Refer: NEC Code 240.4(D)(7)
-
Question 7 of 15
7. Question
1 pointsThe total contact resistance is ______ if measured 5ft from the distance from rod:
Correct
Incorrect
-
Question 8 of 15
8. Question
1 pointsThe portion of the grounding electrode conductor that is the sole connection to one or more concrete encased electrodes is not required to be larger than _____:
Correct
Please Refer: NEC Code 250.66(B)
Incorrect
Please Refer: NEC Code 250.66(B)
-
Question 9 of 15
9. Question
1 pointsGrounding electrode for premises wiring systems must be located no closer than ______ from lightning protection system grounding electrodes:
Correct
Please Refer: NEC Code 250.53(B)
Incorrect
Please Refer: NEC Code 250.53(B)
-
Question 10 of 15
10. Question
1 pointsThe Type 3 SPD connection must be a minimum ______ of conductor distance from the service or separately derived system disconnect:
Correct
Please Refer: NEC Code 285.25
Incorrect
Please Refer: NEC Code 285.25
-
Question 11 of 15
11. Question
1 pointsFMC must be securely fastened within 1 ft of termination and secured and supported at intervals not exceeding ______:
Correct
Please Refer: NEC Code 348.30(A)
Incorrect
Please Refer: NEC Code 348.30(A)
-
Question 12 of 15
12. Question
1 pointsType MC cable can be unsupported for upto _____ past the last point where it is securely fastened to minimize vibration or provide flexibility:
Correct
Please Refer: NEC Code 330.30(D)(3)
Incorrect
Please Refer: NEC Code 330.30(D)(3)
-
Question 13 of 15
13. Question
1 pointsFLC for a single phase AC motor rated 10 hp supplied by 208V is _____ :
Correct
Please Refer: NEC Code Table 430.248
Incorrect
Please Refer: NEC Code Table 430.248
-
Question 14 of 15
14. Question
1 pointsThe short circuit and ground fault protective device must not be less than _____ of the motor compressor current rating:
Correct
Please Refer: NEC Code 440.22(A)
Incorrect
Please Refer: NEC Code 440.22(A)
-
Question 15 of 15
15. Question
1 pointsDry-type transformers rated not more than _____ are permitted above suspended ceilings or in hollow spaces of buildings, if not permanently closed by the structure:
Correct
Please Refer: NEC Code 450.13(B)
Incorrect
Please Refer: NEC Code 450.13(B)