Quiz-summary
0 of 26 questions completed
Questions:
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- 16
- 17
- 18
- 19
- 20
- 21
- 22
- 23
- 24
- 25
- 26
Information
Grounding or Earthing Quiz Questions Answers
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading...
You must sign in or sign up to start the quiz.
You have to finish following quiz, to start this quiz:
Results
0 of 26 questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 points, (0)
Average score |
|
Your score |
|
Categories
- Not categorized 0%
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- 16
- 17
- 18
- 19
- 20
- 21
- 22
- 23
- 24
- 25
- 26
- Answered
- Review
-
Question 1 of 26
1. Question
1 pointsOur earth is a negatively charged body
Correct
Earth is neutrally charged
Incorrect
Earth is neutrally charged
-
Question 2 of 26
2. Question
1 pointsIf the moisture content in the soil increases, resistivity of the soil rises
Correct
Incorrect
-
Question 3 of 26
3. Question
1 pointsWhen the 3-phase system is not grounded and if Single Line to Ground fault occurs, the voltage of the other two healthy phases will:
Correct
Incorrect
-
Question 4 of 26
4. Question
1 pointsElectrical system is grounded in order to protect ___ from faults
Correct
Incorrect
-
Question 5 of 26
5. Question
1 pointsStep potential is associated with the equipment and human body contact potential difference
Correct
Incorrect
-
Question 6 of 26
6. Question
1 pointsElectrical resistivity is inversely proportional to the depth of grounding / earthing rod into the ground
Correct
Incorrect
-
Question 7 of 26
7. Question
1 pointsA resistance shall not be put between the neutral and the ground in a 3-phase circuit
Correct
Incorrect
-
Question 8 of 26
8. Question
1 pointsWhich of the following solution is used to reduces the earth’s resistivity
Correct
Incorrect
-
Question 9 of 26
9. Question
1 pointsA delta-delta connected transformer is grounded with the help of zig-zag transformer:
Correct
Incorrect
-
Question 10 of 26
10. Question
1 pointsIn order to achieve Continuity of the operation even during fault condition which type of the configuration is preferred:
Correct
Incorrect
-
Question 11 of 26
11. Question
1 pointsDuring fault condition, proper earthing will rise the earth potential
Correct
Incorrect
-
Question 12 of 26
12. Question
1 pointsStep Potential is associated with the potential between the two feet separated by about 1 meter
Correct
Incorrect
-
Question 13 of 26
13. Question
1 pointsThe means of bonding shall provide ampacity to flow fault current
Correct
Incorrect
-
Question 14 of 26
14. Question
1 pointsIn an ungrounded system the occurrence of second fault will more likely be ____ than grounded system fault
Correct
Incorrect
-
Question 15 of 26
15. Question
1 pointsThe grounded conductor can be used as the current carrying conductor to accommodate all the non neutral related loads
Correct
Incorrect
-
Question 16 of 26
16. Question
1 pointsThe neutral of any grounded system will permit the flow of current through the conductor when unbalanced load is connected
Correct
Incorrect
-
Question 17 of 26
17. Question
1 pointsHigh voltages originated due to Line to Ground faults in ungrounded system will damage which of the following:
Correct
Incorrect
-
Question 18 of 26
18. Question
1 pointsThe ungrounded system, in reality is a ______ grounding system:
Correct
Incorrect
-
Question 19 of 26
19. Question
1 pointsIn any system (grounding or ungrounding), a ____ coupling exist between the system conductors and the adjacent grounding surfaces:
Correct
Incorrect
-
Question 20 of 26
20. Question
1 pointsIn which of the following system, identification of fault is tedious:
Correct
Incorrect
-
Question 21 of 26
21. Question
1 pointsIn a ungrounded system, if a line to ground fault occurs on one phase, the charging currents (capacitive currents) flowing through the other two healthy phases will be ____ times the normal value:
Correct
Incorrect
-
Question 22 of 26
22. Question
1 pointsIn a ungrounded system, during the fault the protective relays may not able to operate because of the low fault current:
Correct
Incorrect
-
Question 23 of 26
23. Question
1 pointsWhich of the following system produces highest ground fault current when a fault to ground occurs:
Correct
Incorrect
-
Question 24 of 26
24. Question
1 pointsWhich of the following type of grounding system has the highest probability for escalation of ground fault to phase to phase and three phase arcing fault, particularly for low voltage system:
Correct
Incorrect
-
Question 25 of 26
25. Question
1 pointsHigh Resistance grounding typically limits ground fault current under to _____:
Correct
Incorrect
-
Question 26 of 26
26. Question
1 pointsGrounding resistor for high resistance grounding shall be designed such that the ground fault current limit is _____ than the system’s total capacitance to ground charging current inorder to avoid overvoltages:
Correct
Incorrect