Information
Cables NEC Code Quiz Questions Answers 2
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading...
You must sign in or sign up to start the quiz.
You have to finish following quiz, to start this quiz:
Results
0 of 12 questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 points, (0)
Average score |
|
Your score |
|
Categories
- Not categorized 0%
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- Answered
- Review
-
Question 1 of 12
1. Question
1 pointsAttics and roof spaces not accessible by permanent stairs or ladders requires protection for cables only within ____ of the nearest edge of the scuttle hole and attic:
Correct
Please Refer: NEC Code 320.23(A)
Incorrect
Please Refer: NEC Code 320.23(A)
-
Question 2 of 12
2. Question
1 pointsType MC Cable has a bending radius of ____ times the external diameter of the metallic sheath:
Correct
Please Refer: NEC Code 330.24(B)
Incorrect
Please Refer: NEC Code 330.24(B)
-
Question 3 of 12
3. Question
1 pointsType AC Cable must be secured within ____ of every box, cabinet or fitting:
Correct
Please Refer: NEC Code 320.30
Incorrect
Please Refer: NEC Code 320.30
-
Question 4 of 12
4. Question
1 pointsCables installed parallel to framing members shall be installed and supported so that the nearest outside surface of the cable is atleast ______ from the nearest edge of the framing members or furring strip where nails are likely to penetrate:
Correct
Please Refer: NEC Code 300.4(D)
Incorrect
Please Refer: NEC Code 300.4(D)
-
Question 5 of 12
5. Question
1 pointsConductors associated with air handling spaces in dwelling units must remain at least _____ from the nearest edge of the wood members:
Correct
Please Refer: NEC Code 300.4(A)(1)
Incorrect
Please Refer: NEC Code 300.4(A)(1)
-
Question 6 of 12
6. Question
1 points____ Cables shall have an internal bonding strip in intermediate contact with the armor for its entire length:
Correct
Please Refer: NEC Code 320.100
Incorrect
Please Refer: NEC Code 320.100
-
Question 7 of 12
7. Question
1 pointsExposed Runs of Type MC Cables must be supported and secured at intervals of ____ or less:
Correct
Please Refer: NEC Code 330.30(B)
Incorrect
Please Refer: NEC Code 330.30(B)
-
Question 8 of 12
8. Question
1 pointsInterlocking armor Type MC Cable requires an equipment grounding conductor:
Correct
Incorrect
-
Question 9 of 12
9. Question
1 pointsThe nearest outside surface of installed and supported exposed non metallic sheathed cable in unfinished basements and crawl spaces must be atleast ____ from the nearest edge of the framing members where nails or screws are likely to penetrate:
Correct
Please Refer: NEC Code 300.4(A)(1)Incorrect
Please Refer: NEC Code 300.4(A)(1) -
Question 10 of 12
10. Question
1 pointsThe White and Gray conductors shall not be used as a return conductor from the switch to the outlet:
Correct
Please Refer: NEC Code 200.7(C)(1)
Incorrect
Please Refer: NEC Code 200.7(C)(1)
-
Question 11 of 12
11. Question
1 pointsDirect buried conductors and cables emerging from the ground must be protected by enclosures and raceways:
Correct
Please Refer: NEC Code 300.5(D)(1)
Incorrect
Please Refer: NEC Code 300.5(D)(1)
-
Question 12 of 12
12. Question
1 pointsMinimum cover required for 600V direct burial cables or conductors in a trench below 50mm thick concrete or equivalent is _____:
Correct
Please Refer: NEC Code – Table 300.5
Incorrect
Please Refer: NEC Code – Table 300.5