Information
NEC Code Practice Tests Quiz Questions Answers Exam 11
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading...
You must sign in or sign up to start the quiz.
You have to finish following quiz, to start this quiz:
Results
0 of 15 questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 points, (0)
Average score |
|
Your score |
|
Categories
- Not categorized 0%
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- Answered
- Review
-
Question 1 of 15
1. Question
1 pointsThe disconnect can consists of upto ______ switches or circuit breakers mounted in a single enclosures, or in a group of separate enclosures:
Correct
Please Refer: NEC Code 225.33(A)
Incorrect
Please Refer: NEC Code 225.33(A)
-
Question 2 of 15
2. Question
1 pointsConductors are considered outside the building when encased or installed under not less than ______ of the concrete:
Correct
Please Refer: NEC Code 230.6
Incorrect
Please Refer: NEC Code 230.6
-
Question 3 of 15
3. Question
1 pointsElectrode premise wiring systems mus be located no closer than _____ from lightning protection system grounding electrodes:
Correct
Please Refer: NEC Code 250.53(B)
Incorrect
Please Refer: NEC Code 250.53(B)
-
Question 4 of 15
4. Question
1 pointsWhen multiple grounding electrode conductors are installed, each grounding electrode conductor is permitted to terminate to any grounding electrode of the grounding electrode system:
Correct
Please Refer: NEC Code 250.64(F)(2)
Incorrect
Please Refer: NEC Code 250.64(F)(2)
-
Question 5 of 15
5. Question
1 pointsA Surge protection device must not be used in circuits that exceed _____ :
Correct
Please Refer: NEC Code 285.3
Incorrect
Please Refer: NEC Code 285.3
-
Question 6 of 15
6. Question
1 pointsWhen structural members does not permit the raceway to be secured within 3 ft of a box or termination fitting, the raceway must be secured within ______ of the termination:
Correct
Please Refer: NEC Code 344.30(A)(2)
Incorrect
Please Refer: NEC Code 344.30(A)(2)
-
Question 7 of 15
7. Question
1 pointsIntermediate metal conduit must generally be supported at an intervals not exceeding _______ :
Correct
Please Refer: NEC Code 342.30(B)(1)
Incorrect
Please Refer: NEC Code 342.30(B)(1)
-
Question 8 of 15
8. Question
1 pointsA smooth inner surface with integral reinforcement within the raceway wall:
Correct
Please Refer: NEC Code 356.2(2)
Incorrect
Please Refer: NEC Code 356.2(2)
-
Question 9 of 15
9. Question
1 pointsPVC conduit can be concealed within walls, floors, or ceilings, directly buried or embedded in concrete in buildings of any height:
Correct
Please Refer: NEC Code 350.10(A)
Incorrect
Please Refer: NEC Code 350.10(A)
-
Question 10 of 15
10. Question
1 pointsThe distance from the raceway entry of the box or conduit body to the opposite wall must not be less than _____ times the trade size of the largest raceway, plus the sum of the trade sizes of the remaining raceways on the same wall and row:
Correct
Please Refer: NEC Code 314.28(A)(2)
Incorrect
Please Refer: NEC Code 314.28(A)(2)
-
Question 11 of 15
11. Question
1 pointsThe overcurrent protection of panelboards can be located within or on the supply side of the panelboard:
Correct
Please Refer: NEC Code 408.36
Incorrect
Please Refer: NEC Code 408.36
-
Question 12 of 15
12. Question
1 pointsCloset storage space continues vertically to the closet ceiling for a distance of ______ or the width of the shelf whichever is greater:
Correct
Please Refer: NEC Code 410.2
Incorrect
Please Refer: NEC Code 410.2
-
Question 13 of 15
13. Question
1 pointsConductors within ______ of ballast, LED driver, power supply or transformer must have an insulation temperature rating not lower than 90oC
Correct
Please Refer: NEC Code 410.68
Incorrect
Please Refer: NEC Code 410.68
-
Question 14 of 15
14. Question
1 pointsA point in the wiring system where the electrical current is taken to the supply a load:
Correct
Please Refer: NEC Code 100
Incorrect
Please Refer: NEC Code 100
-
Question 15 of 15
15. Question
1 pointsA device intended to protect people by den-energizing a circuit when a current imbalance has been detected that exceeds the value established:
Correct
Please Refer: NEC Code 100
Incorrect
Please Refer: NEC Code 100