Quiz-summary
0 of 19 questions completed
Questions:
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- 16
- 17
- 18
- 19
Information
NEC Code Practice Tests Quiz Questions Answers 2
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading...
You must sign in or sign up to start the quiz.
You have to finish following quiz, to start this quiz:
Results
0 of 19 questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 points, (0)
Average score |
|
Your score |
|
Categories
- Not categorized 0%
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- 16
- 17
- 18
- 19
- Answered
- Review
-
Question 1 of 19
1. Question
1 pointsSplices and taps must be accessible and must not fill raceway to more than _____ of its cross-sectional area:
Correct
Please Refer: NEC Code 386.56
Incorrect
-
Question 2 of 19
2. Question
1 pointsFlexible cords is permitted to be run through holes in walls, structural ceilings, suspended or dropped ceilings or floors:
Correct
Please Refer: NEC Code 400.8
Incorrect
Please Refer: NEC Code 400.8
-
Question 3 of 19
3. Question
1 pointsA switch or circuit breaker enclosure may be used as a raceway if the conductor fill doesnot exceed _____ :
Correct
Please Refer: NEC Code 312.2
Incorrect
Please Refer: NEC Code 312.2
-
Question 4 of 19
4. Question
1 pointsReceptacles located more than _____ above the floor are not required to be tamper resistant:
Correct
Please Refer: NEC Code 406.12(C) Exp (1)
Incorrect
Please Refer: NEC Code 406.12(C) Exp (1)
-
Question 5 of 19
5. Question
1 pointsThe total rating of a cord and plug connected room air conditioner must not exceed ______ of the rating of a branch circuit where lighting outlets, other appliances, or general use receptacles are also supplied
Correct
Please Refer: NEC Code 440.62(C)
Incorrect
-
Question 6 of 19
6. Question
1 pointsA portable generator is required to be grounded if the generator only supplies receptacles mounted on the generator
Correct
Please Refer: NEC Code 230.54(A)
Incorrect
Please Refer: NEC Code 230.54(A)
-
Question 7 of 19
7. Question
1 pointsThe ground detection sensing equipment must be connected as close as practicable to where the system receives its power supply:
Correct
Please Refer: NEC Code 250.21(C)
Incorrect
Please Refer: NEC Code 250.21(C)
-
Question 8 of 19
8. Question
1 points______ circuit breakers or sets of fuses are acceptable as over current device to provide overload protection in one family dwellings:
Correct
Please Refer: NEC Code 230.90(A)
Incorrect
Please Refer: NEC Code 230.90(A)
-
Question 9 of 19
9. Question
1 pointsThe overhead service conductors above a roof with a slope of at least 4.in in 12.in have a minimum clearance of ______:
Correct
Please Refer: NEC Code 230.24(A) exp-2
Incorrect
Please Refer: NEC Code 230.24(A) exp-2
-
Question 10 of 19
10. Question
1 pointsA two pole circuit breaker or fusible switch shall be considered as _____ over current devices:
Correct
Please Refer: NEC Code 408.54
Incorrect
Please Refer: NEC Code 408.54
-
Question 11 of 19
11. Question
1 pointsAt least _____ of free conductor, measured from the point in the box where it emerges from its raceway or cable sheath shall be left at each outlet, junction and switch point:
Correct
Please Refer: NEC Code 300.14
Incorrect
Please Refer: NEC Code 300.14
-
Question 12 of 19
12. Question
1 points_____ is the maximum approved electrical trade size for PVC conduit:
Correct
Please Refer: NEC Code 352.20(B)
Incorrect
Please Refer: NEC Code 352.20(B)
-
Question 13 of 19
13. Question
1 pointsCeiling grid which supports the wires may be permitted to support raceways:
Correct
Incorrect
-
Question 14 of 19
14. Question
1 pointsReceptacles must be mounted ____ or more above the deck surface of the pier:
Correct
Please Refer: NEC Code 555.19
Incorrect
Please Refer: NEC Code 555.19
-
Question 15 of 19
15. Question
1 pointsThe feeder circuit for a mobile or a mobile or manufactured home must be rated at not less than ____ at 120/240V
Correct
Please Refer: NEC Code 550.33
Incorrect
Please Refer: NEC Code 550.33
-
Question 16 of 19
16. Question
1 pointsGFCI protection is required for ____, 125V, general purpose receptacles located in dirt confinement areas for livestock:
Correct
Please Refer: NEC Code 547.5(G)(4)
Incorrect
Please Refer: NEC Code 547.5(G)(4)
-
Question 17 of 19
17. Question
1 pointsExcept for storable pools, fixed or stationary equipment other than an underwater luminaire cord must not exceed ____ in length:
Correct
Please Refer: NEC Code 680.7
Incorrect
Please Refer: NEC Code 680.7
-
Question 18 of 19
18. Question
1 pointsCables listed for information technology equipment can be used to interconnect information technology equipment without the _____ cable length limited
Correct
Please Refer: NEC Code 645.5(B)(1)
Incorrect
Please Refer: NEC Code 645.5(B)(1)
-
Question 19 of 19
19. Question
1 pointsThe coupling means of the Electric Vehicle supply equipment must be stored or located not less than _____ above the floor level:
Correct
Please Refer: NEC Code 625.50
Incorrect
Please Refer: NEC Code 625.50