Information
NEC Code Practice Tests Quiz Questions Answers 4
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading...
You must sign in or sign up to start the quiz.
You have to finish following quiz, to start this quiz:
Results
0 of 19 questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 points, (0)
Average score |
|
Your score |
|
Categories
- Not categorized 0%
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- 16
- 17
- 18
- 19
- Answered
- Review
-
Question 1 of 19
1. Question
1 pointsUnderground metal water pipe is direct contact with the earth for ______ or more can serve as a grounding electrode:
Correct
Please Refer: NEC Code 250.52(A)(1)
Incorrect
Please Refer: NEC Code 250.52(A)(1)
-
Question 2 of 19
2. Question
1 pointsThe supplemental electrode for a rod electrode must be installed not less than _____ from the rod electrode:
Correct
Please Refer: NEC Code 250.53(A)(3)
Incorrect
Please Refer: NEC Code 250.53(A)(3)
-
Question 3 of 19
3. Question
1 pointsA ground ring electrode that encircling the building consisting of atleast _______ of bare copper conductor:
Correct
Please Refer: NEC Code 250.53(A)(D)(2)(F)
Incorrect
Please Refer: NEC Code 250.53(A)(D)(2)(F)
-
Question 4 of 19
4. Question
1 pointsSurge Protection Devices must not be used in circuits that exceed _____ :
Correct
Please Refer: NEC Code 285.3(1)
Incorrect
Please Refer: NEC Code 285.3(1)
-
Question 5 of 19
5. Question
1 pointsInsulated equipment grounding conductors _____ and larger can be permanently reidentified at the time of installation at every point where the conductor is accessible:
Correct
Please Refer: NEC Code 250.119(1)
Incorrect
Please Refer: NEC Code 250.119(1)
-
Question 6 of 19
6. Question
1 pointsThe over Current protection for 12AWG copper conductors must not exceed ———–;
Correct
Please Refer: NEC Code 240.4(D)(5)
Incorrect
Please Refer: NEC Code 240.4(D)(5)
-
Question 7 of 19
7. Question
1 pointsThe Ampacity of service entrance conductors must be ——– of the continuous nodes connected;
Correct
Please Refer: NEC Code 230.42(A)(1)
Incorrect
Please Refer: NEC Code 230.42(A)(1)
-
Question 8 of 19
8. Question
1 pointsThe point of attachment of overhead service conductors must not be less than ——– above the finished grade;
Correct
Please Refer: NEC Code 230.26
Incorrect
Please Refer: NEC Code 230.26
-
Question 9 of 19
9. Question
1 pointsConductors are considered outside of a building when they are installed under not less than ——— of concrete beneath the building;
Correct
Please Refer: NEC Code 230.6(1)
Incorrect
Please Refer: NEC Code 230.6(1)
-
Question 10 of 19
10. Question
1 pointsA cord is permitted for a dishwasher if the length is atleast ——- measured from the rear plane of the appliance;
Correct
Please Refer: NEC Code 422.16(B)(2)
Incorrect
Please Refer: NEC Code 422.16(B)(2)
-
Question 11 of 19
11. Question
1 pointsCord and plug connected equipment must not be rated more than ——– of the branch circuit ampere rating;
Correct
Please Refer: NEC Code 210.23(A)(1)
Incorrect
Please Refer: NEC Code 210.23(A)(1)
-
Question 12 of 19
12. Question
1 pointsA circuit breaker can serve as motor controller;
Correct
Please Refer: NEC Code 430.111
Incorrect
Please Refer: NEC Code 430.111
-
Question 13 of 19
13. Question
1 pointsThe Ampere rating of hermetic refrigerant motor compressor must be atleast —— of the name plate rated load current;
Correct
Please Refer: NEC Code 445.12(A)(1)
Incorrect
Please Refer: NEC Code 445.12(A)(1)
-
Question 14 of 19
14. Question
1 pointsLand area subject to tidal function is defined as the horizontal plane ___ above the highest high tide that occurs under normal circumstances:
Correct
Please Refer: NEC Code 555.2
Incorrect
Please Refer: NEC Code 555.2
-
Question 15 of 19
15. Question
1 pointsFixed lighting over travel lines, or if exposed to physical damage must be located not less than ____ above floor level, unless the luminaire is of the totally enclosed type or constructed to prevent sparks or hot metal particles from escaping:
Correct
Please Refer: NEC Code 511.7(B)
Incorrect
Please Refer: NEC Code 511.7(B)
-
Question 16 of 19
16. Question
1 pointsFor a fixed pier, all electrical connections must be located not less than ____ above the deck:
Correct
Please Refer: NEC Code 555.9
Incorrect
Please Refer: NEC Code 555.9
-
Question 17 of 19
17. Question
1 pointsEach branch circuit or feeder that supplies a sign installed with in a fountain, or within ____ of the fountain edge, must be GFCI protected:
Correct
Please Refer: NEC Code 680.57(B)
Incorrect
Please Refer: NEC Code 680.57(B)
-
Question 18 of 19
18. Question
1 pointsThe overcurrent device provide for the protection of overcurrent protection for an assembly of fire pump must not open with a restart transient of ____ times the full load current of the fire pump motors:
Correct
Please Refer: NEC Code 695.4(B)(2)(a)(1)
Incorrect
Please Refer: NEC Code 695.4(B)(2)(a)(1)
-
Question 19 of 19
19. Question
1 pointsAt least one 15A or 20A, 125V receptacles must be located at least ____ from the inside wall of the spa or hot tub:
Correct
Please Refer: NEC Code 680.43(A)
Incorrect
Please Refer: NEC Code 680.43(A)