Raceways and Conductors NEC Code Quiz Questions Answers 4
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading...
You must sign in or sign up to start the quiz.
You have to finish following quiz, to start this quiz:
Results
0 of 10 questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 points, (0)
Average score |
|
Your score |
|
Categories
- Not categorized 0%
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- Answered
- Review
-
Question 1 of 10
1. Question
1 pointsGalvanized steel and stainless steel RMC can be used under all atmospheric conditions, within all types of occupancies:
Correct
Please Refer: NEC Code 344.10(A)(1)
Incorrect
Please Refer: NEC Code 344.10(A)(1)
-
Question 2 of 10
2. Question
1 pointsThe minimum approved electrical trade size for RMC is _____:
Correct
Please Refer: NEC Code 344.20(A)
Incorrect
Please Refer: NEC Code 344.20(A)
-
Question 3 of 10
3. Question
1 pointsIf the structural members are not available within 3 ft, a distance of _____ is acceptable for IMC and RMC:
Correct
Please Refer: NEC Code 342.30(A)(2) and 344.30(A)
Incorrect
Please Refer: NEC Code 342.30(A)(2) and 344.30(A)
-
Question 4 of 10
4. Question
1 pointsCoupled with listed fittings, IMC provides electrical continuity and therefore it can serve as equipment grounding conductor:
Correct
Please Refer: NEC Code 342.2 and 342.60
Incorrect
Please Refer: NEC Code 342.2 and 342.60
-
Question 5 of 10
5. Question
1 pointsNormally EMT must be fastened within _____ of the device box:
Correct
Incorrect
-
Question 6 of 10
6. Question
1 pointsThe maximum approved electrical trade size for IMC is _____:
Correct
Please Refer: NEC Code 342.20(B)
Incorrect
Please Refer: NEC Code 342.20(B)
-
Question 7 of 10
7. Question
1 pointsSchedule 40 PVC is an extra heavy walled raceway with a wall thickness confirming to Schedule 80 iron pipe size (IPS) dimensions:
Correct
Incorrect
-
Question 8 of 10
8. Question
1 pointsSecuring is not required for ENT in lengths not more than ____ from a luminaire terminal connection:
Correct
Please Refer: NEC Code 362.30(A)
Incorrect
Please Refer: NEC Code 362.30(A)
-
Question 9 of 10
9. Question
1 pointsENT must be securely fastened in place within ____ of all termination points:
Correct
Please Refer: NEC Code 362.30(A)
Incorrect
Please Refer: NEC Code 362.30(A)
-
Question 10 of 10
10. Question
1 pointsHoles must be bored so that the edge of the hole is atleast _____ from the nearest edge of the wood members:
Correct
Please Refer: NEC Code 300.4(A)(1)
Incorrect
Please Refer: NEC Code 300.4(A)(1)