Quiz-summary
0 of 19 questions completed
Questions:
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- 16
- 17
- 18
- 19
Information
Solar PV Electrician License Quiz Test
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading...
You must sign in or sign up to start the quiz.
You have to finish following quiz, to start this quiz:
Results
0 of 19 questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 points, (0)
Average score |
|
Your score |
|
Categories
- Not categorized 0%
-
Congrats, You Passed the Test
-
Sorry, You did not Pass
-
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- 16
- 17
- 18
- 19
- Answered
- Review
-
Question 1 of 19
1. Question
1 pointsIn a three wire PV system, the neutral or center tap of the dc system shall be grounded
Correct
Incorrect
-
Question 2 of 19
2. Question
1 pointsProper grounding of PV system will:
Correct
Incorrect
-
Question 3 of 19
3. Question
1 pointsBare, green insulation or green with yellow stripes insulation is generally used for which type of conductors
Correct
Incorrect
-
Question 4 of 19
4. Question
1 pointsGrounded Conductors are conductors which does not carry current normally and is connected to exposed metal portions of the equipment and ground
Correct
Incorrect
-
Question 5 of 19
5. Question
1 pointsIf the conductor between the dc battery and inverter is 4/0 AWG, then the ground electrode conductor connecting the negative conductor to ground electrode will be ____
Correct
Incorrect
-
Question 6 of 19
6. Question
1 pointsThe dc system-grounding electrode conductor shall not be smaller than 4 AWG or the largest conductor supplied by the system
Correct
Incorrect
-
Question 7 of 19
7. Question
1 pointsGround mounted arrays are not required to have ground fault detection devices
Correct
Incorrect
-
Question 8 of 19
8. Question
1 pointsGFID devices can perform which of the following functions
Correct
Incorrect
-
Question 9 of 19
9. Question
1 pointsThe output voltage may be made zero by short circuiting the PV module or array terminals
Correct
Incorrect
-
Question 10 of 19
10. Question
1 pointsIn a PV system, Grounding conductors which normally remain connected all the times may be provided with ____ disconnecting means
Correct
Incorrect
-
Question 11 of 19
11. Question
1 pointsEach piece of equipment in the PV system shall have disconnecting switches to disconnect it from all the sources of power’
Correct
Incorrect
-
Question 12 of 19
12. Question
1 pointsUngrounded Conductors carrying current from PV power source shall be provided with which type of disconnecting means
Correct
Incorrect
-
Question 13 of 19
13. Question
1 pointsPV System shall not be remain connected the load when the battery is taken out in a stand alone system either manually or through action of fuse or circuit breaker operation
Correct
Incorrect
-
Question 14 of 19
14. Question
1 pointsIn order to shut down the entire system with minimum number of switching actions, circuit breakers and switches shall be of ganged mutlipole units
Correct
Incorrect
-
Question 15 of 19
15. Question
1 pointsFuse or circuit breakers shall be ganged or paralleled to increase the current carrying capacity of the devices
Correct
Incorrect
-
Question 16 of 19
16. Question
1 pointsHigh short circuit current of PV array are less significant as they are inherently current limited
Correct
Incorrect
-
Question 17 of 19
17. Question
1 pointsShort circuit condition is less severe for stand alone systems with storage batteries as batteries are inherently current limited
Correct
Incorrect
-
Question 18 of 19
18. Question
1 pointsFor dc systems, especially for stand alone systems with storage batteries, the interrupting capacity of each over current device is specified as:
Correct
Incorrect
-
Question 19 of 19
19. Question
1 pointsHigh short circuit currents will generate excessive ______ that can cause devices to blow apart or burn
Correct
Incorrect