Single Family Dwelling NEC Code Questions
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading...
You must sign in or sign up to start the quiz.
You have to finish following quiz, to start this quiz:
Results
0 of 15 questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 points, (0)
Average score |
|
Your score |
|
Categories
- Not categorized 0%
-
Congrats, You Passed the Test
-
Sorry, You did not Pass
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- Answered
- Review
-
Question 1 of 15
1. Question
1 pointsThe front edge of the cabinets situated in walls constructed of noncombustible materials such as concrete and tile must be within ____ of the finished surface:
Correct
Please Refer: NEC Code 312.3
Incorrect
Please Refer: NEC Code 312.3
-
Question 2 of 15
2. Question
1 pointsService disconnect means shall not be located inside a building or structure.
Correct
Please Refer: NEC Code 230.70(A)1
Incorrect
Please Refer: NEC Code 230.70(A)1
-
Question 3 of 15
3. Question
1 pointsEach ungrounded and grounded service conductor shall be provided with the overload protection
Correct
Please Refer: NEC Code 230.90
Incorrect
Please Refer: NEC Code 230.90
-
Question 4 of 15
4. Question
1 pointsDrip Loops must be formed on each individual conductors
Correct
Please Refer: NEC Code 230.54(F)
Incorrect
Please Refer: NEC Code 230.54(F)
-
Question 5 of 15
5. Question
1 pointsWhere it is impracticable to locate the service head above the point of attachment, the service head must be located within _____ of the point
Correct
Please Refer: NEC Code 230.54(C) Exception
Incorrect
Please Refer: NEC Code 230.54(C) Exception
-
Question 6 of 15
6. Question
1 pointsService Entrance Cables must be supported at intervals not to exceed ____
Correct
Please Refer: NEC Code 230.51(A)
Incorrect
Please Refer: NEC Code 230.51(A)
-
Question 7 of 15
7. Question
1 pointsConductors installed under _____ or more of concrete beneath a building (or other structure) are considered outside:
Correct
Please Refer: NEC Code 230.6(1)
Incorrect
Please Refer: NEC Code 230.6(1)
-
Question 8 of 15
8. Question
1 pointsOverhead conductors accessible only to pedestrian traffic must have a minimum ____ vertical clearance above finished grade, sidewalks and platforms:
Correct
Please Refer: NEC Code 225.18(1)
Incorrect
Please Refer: NEC Code 225.18(1)
-
Question 9 of 15
9. Question
1 pointsA drip loops lowest point of service drop conductors has a minimum vertical clearance of ____
Correct
Please Refer: NEC Code 230.24(B)1
Incorrect
Please Refer: NEC Code 230.24(B)1
-
Question 10 of 15
10. Question
1 pointsThe 3 feet clearance requirement does not apply to conductors run above the top level of the window
Correct
Please Refer: NEC Code 230.9(A)
Incorrect
Please Refer: NEC Code 230.9(A)
-
Question 11 of 15
11. Question
1 pointsA disconnecting means is not required if the branch-circuit switch or circuit breaker is within ____ and can be seen while working on the appliance:
Correct
Please Refer: NEC Code 422.31(B)
Incorrect
Please Refer: NEC Code 422.31(B)
-
Question 12 of 15
12. Question
1 pointsAt least 2 receptacles are required in each detached garage with electric power
Correct
Please Refer: NEC Code 210.52(G)
Incorrect
Please Refer: NEC Code 210.52(G)
-
Question 13 of 15
13. Question
1 pointsA permanently connected appliance rated over _____ requires a means to disconnect all ungrounded (hot) conductors from the appliance
Correct
Please Refer: NEC Code 422.30
Incorrect
Please Refer: NEC Code 422.30
-
Question 14 of 15
14. Question
1 pointsLaundry receptacle outlets shall be fed from a ____ branch circuit
Correct
Please Refer: NEC Code 210.11(C)(2)
Incorrect
Please Refer: NEC Code 210.11(C)(2)
-
Question 15 of 15
15. Question
1 pointsWall mounted ovens and counter mounted cooking units may be connected permanently or by cord and plug:
Correct
Please Refer: NEC Code 422.16(A)(3)
Incorrect
Please Refer: NEC Code 422.16(A)(3)