NEC Quiz – Recreation Room
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading...
You must sign in or sign up to start the quiz.
You have to finish following quiz, to start this quiz:
Results
0 of 10 questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 points, (0)
Average score |
|
Your score |
|
Categories
- Not categorized 0%
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- Answered
- Review
-
Question 1 of 10
1. Question
1 pointsReceptacles installed within _____ of the outside edge of a sink be GFCI protected.
Correct
Please Refer: NEC Code 210.8(A)
Incorrect
Please Refer: NEC Code 210.8(A)
-
Question 2 of 10
2. Question
1 pointsAll ungrounded conductors of a branch circuit to be disconnected simultaneously at the point the branch circuit originates
Correct
Please Refer: NEC Code 210.4(B)
Incorrect
Please Refer: NEC Code 210.4(B)
-
Question 3 of 10
3. Question
1 pointsReceptacles shall be installed face up on the counter-top surfaces or work surfaces.
Correct
Please Refer: NEC Code 406.4(E)
Incorrect
Please Refer: NEC Code 406.4(E)
-
Question 4 of 10
4. Question
1 pointsThe purpose of the grounding electrode system is to carry current for faulty circuits in the building or between the building and the utility transformer.
Correct
Incorrect
-
Question 5 of 10
5. Question
1 pointsThe path through the earth is not an effective ground-fault return path:
Correct
Please Refer: NEC Code 250.4(A)(5)
Incorrect
Please Refer: NEC Code 250.4(A)(5)
-
Question 6 of 10
6. Question
1 pointsAll 120-volt, single phase, 15- and 20-ampere branch circuits supplying outlets installed in
recreation shall be protected by a AFCI:Correct
Incorrect
-
Question 7 of 10
7. Question
1 pointsIf the black and red conductors of the 3-wire cable are connected to the same phase in Panel A the neutral conductor must carry the unbalanced current
Correct
Carry total current of both the red and black conductors
Incorrect
Neutral carry total current of both the red and black conductors
-
Question 8 of 10
8. Question
1 pointsIf the black and red conductors of the 3-wire cable are connected to the same phase in Panel A the neutral conductor must carry the unbalanced current
Correct
Carry total current of both the red and black conductors
Incorrect
Neutral carry total current of both the red and black conductors
-
Question 9 of 10
9. Question
1 points3-wire branch circuit will have more voltage drop in the conductors
Correct
Incorrect
-
Question 10 of 10
10. Question
1 pointsIn case of 3-wire branch circuit, if the neutral conductor opens this results in possible burnout:
Correct
Incorrect