Question 1 of 12
1. Question
1 pointsType MC Cables must be supported and secured at intervals not exceeding _____:
Correct
Please Refer: NEC Code 330.30
Incorrect
Please Refer: NEC Code 330.30
-
Question 2 of 12
2. Question
1 pointsType AC Cable must have a bending radius at least _____ times the diameter of the cable:
Correct
Please Refer: NEC Code 320.24
Incorrect
Please Refer: NEC Code 320.24
-
Question 3 of 12
3. Question
1 pointsCables must be secured within ____ of every box, cabinet or fittings:
Correct
Incorrect
-
Question 4 of 12
4. Question
1 pointsProtection is required for the cables located within ____ of the attic entrance:
Correct
Incorrect
-
Question 5 of 12
5. Question
1 pointsCables more than ____ above the floor (or floor joints) can run across the face of the framing members:
Correct
Incorrect
-
Question 6 of 12
6. Question
1 pointsType AC Cable shall not have a flexible meal tape armor
Correct
Please Refer: NEC Code 320.100
Incorrect
Please Refer: NEC Code 320.100
-
Question 7 of 12
7. Question
1 pointsEquipotential grounding conductor can be bare, covered or insulated:
Correct
Please Refer: NEC Code 250.119
Incorrect
Please Refer: NEC Code 250.119
-
Question 8 of 12
8. Question
1 pointsType MC and Type MI Cables that are identified as direct burial can be installed under a building without a raceway:
Correct
Please Refer: NEC Code 300.5(C)
Incorrect
Please Refer: NEC Code 300.5(C)
-
Question 9 of 12
9. Question
1 pointsType MV is a single dielectric insulated cable rated _____ volts or higher:
Correct
Please Refer: NEC Code 328.2
Incorrect
Please Refer: NEC Code 328.2
-
Question 10 of 12
10. Question
1 pointsNon metallic sheathed cable (secured to the box) must be secured within ___ of each box, cabinet or fitting:
Correct
Please Refer: NEC Code 334.30
Incorrect
Please Refer: NEC Code 334.30
-
Question 11 of 12
11. Question
1 pointsCables entering or exiting conduit used for support or protection against physical damage require fittings on the conduit ends to prevent:
Correct
Please Refer: NEC Code 300.15(C)
Incorrect
Please Refer: NEC Code 300.15(C)
-
Question 12 of 12
12. Question
1 pointsExposed Runs of Type MC Cable must be supported at intervals of _____ or less:
Correct
Please Refer: NEC Code 330.30(B)
Incorrect
Please Refer: NEC Code 330.30(B)