Commercial Locations NEC Quiz Questions Answers 3
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading...
You must sign in or sign up to start the quiz.
You have to finish following quiz, to start this quiz:
Results
0 of 12 questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 points, (0)
Average score |
|
Your score |
|
Categories
- Not categorized 0%
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- Answered
- Review
-
Question 1 of 12
1. Question
1 pointsA single piece of the equipment consisting of four or more receptacles must be calculated at not less than _____ per receptacles:
Correct
Please Refer: NEC Code 220.14(I)
Incorrect
Please Refer: NEC Code 220.14(I)
-
Question 2 of 12
2. Question
1 points_____ number of receptacles are permitted on a 15-ampere overcurrent protective device:
Correct
Incorrect
-
Question 3 of 12
3. Question
1 pointsMultioutlet assemblies with two receptacles per ft having a rating of _____ for two receptacles
Correct
Incorrect
-
Question 4 of 12
4. Question
1 pointsThe overcurrent device on a branch circuit supplying continuous loads shall be rated at least _____ of the load:
Correct
Please Refer: NEC Code 210.20(A)
Incorrect
Please Refer: NEC Code 210.20(A)
-
Question 5 of 12
5. Question
1 pointsA pole longer than ____ supporting a luminaire(s) requires a handhole:
Correct
Please Refer: NEC Code 410.30(B)(1)
Incorrect
Please Refer: NEC Code 410.30(B)(1)
-
Question 6 of 12
6. Question
1 pointsA portable handlamps supplied through an isolating transformer with an ungrounded secondary of not over _____ do not require grounding:
Correct
Please Refer: NEC Code 410.82(B)
Incorrect
Please Refer: NEC Code 410.82(B)
-
Question 7 of 12
7. Question
1 pointsA load expected to continue at maximum current for ____ hours or more is a continuous load:
Correct
Please Refer: NEC Code 100
Incorrect
Please Refer: NEC Code 100
-
Question 8 of 12
8. Question
1 pointsA recessed luminaire not identified for contact with insulation shall have all recessed parts spaced at least _____ from the combustible materials:
Correct
Please Refer: NEC Code 410.116(A)(1)
Incorrect
Please Refer: NEC Code 410.116(A)(1)
-
Question 9 of 12
9. Question
1 pointsThermal insulation shall not be installed above a recessed luminaire or within ____ of the recessed luminaire’s enclosure, wiring compartment, ballast, transformer, LED driver or power supply unless the luminaire is identified as Type IC for insulation contact:
Correct
Please Refer: NEC Code 410.116(B)
Incorrect
Please Refer: NEC Code 410.116(B)
-
Question 10 of 12
10. Question
1 points_____ branch circuit cannot supply fixed lighting units with heavy duty lampholders in other than dwelling units:
Correct
Please Refer: NEC Code 210.23(B) and (C)
Incorrect
Please Refer: NEC Code 210.23(B) and (C)
-
Question 11 of 12
11. Question
1 pointsBathroom receptacles is required only in nondwelling units, hotels, or motel guest rooms and sleeping rooms in dormitories:
Correct
Please Refer: NEC Code 210.52(D) and 210.60(A)
Incorrect
Please Refer: NEC Code 210.52(D) and 210.60(A)
-
Question 12 of 12
12. Question
1 pointsThe outlet(s) must be supplied by a branch circuit rated _____ or more and that supplies no other load:
Correct
Please Refer: NEC Code 600.5(A)
Incorrect
Please Refer: NEC Code 600.5(A)