Switchboards and Panel-boards Quiz Questions
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading...
You must sign in or sign up to start the quiz.
You have to finish following quiz, to start this quiz:
Results
0 of 18 questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 points, (0)
Average score |
|
Your score |
|
Categories
- Not categorized 0%
-
Congrats, You Passed the Test
-
Sorry, You did not Pass
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- 16
- 17
- 18
- Answered
- Review
-
Question 1 of 18
1. Question
1 pointsBarriers are required in service switch boards to provide the physical separation between the load terminals and the service busbar and the terminals:
Correct
Please Refer: NEC Code 408.3 (A) 2
Incorrect
Please Refer: NEC Code 408.3 (A) 2
-
Question 2 of 18
2. Question
1 pointsDe-energizing the load side of the switchboard by operating the disconnecting means will de-energize the ungrounded service conductors:
Correct
Please Refer: NEC Code 408.3 (A)
Incorrect
Please Refer: NEC Code 408.3 (A)
-
Question 3 of 18
3. Question
1 pointsHorizontal travel of conductors through more than one section of the multi section switchboard is necessary where a raceway or cable entry is made into the switchboard section other than one at which the conductors are terminated
Correct
Please Refer: NEC Code 408.3 (A) (3)
Incorrect
Please Refer: NEC Code 408.3 (A) (3)
-
Question 4 of 18
4. Question
1 pointsEach Switchboard if used as a service equipment, shall be provided with a main bonding jumper
Correct
Please Refer: NEC Code 408.3 (C)
Incorrect
Please Refer: NEC Code 408.3 (C)
-
Question 5 of 18
5. Question
1 pointsThe high leg is common on 3-phase and 4 wire delta system and is typically designated as:
Correct
Please Refer: NEC Code 408 (E)
Incorrect
Please Refer: NEC Code 408 (E)
-
Question 6 of 18
6. Question
1 pointsWhen a ground fault occurs on 3-phase ungrounded system, the voltage to the ground on a ungrounded system may be equal to line to phase voltage
Correct
Will be equal to Line to Line Voltage
Incorrect
Equal to Line to Line Voltage
-
Question 7 of 18
7. Question
1 pointsFor ungrounded system above 600V and below 1000V Ground Fault Detectors shall be provided for warning purpose
Correct
Please Refer: NEC Code 250.21 (B)
Incorrect
Please Refer: NEC Code 250.21 (B)
For Voltages above 120V and below 1000V
-
Question 8 of 18
8. Question
1 pointsAll the switchboards and panelboards supplied by the feeders in two family dwelling shall be marked to indicate the device or equipment where the power supply originates:
Correct
Please Refer: NEC Code 408.4 (B)
Incorrect
Please Refer: NEC Code 408.4 (B)
-
Question 9 of 18
9. Question
1 pointsCircuit directory is important feature for safe operation of an electrical system under normal and emergency conditions
Correct
Please Refer: NEC Code 408.4 (A)
Incorrect
Please Refer: NEC Code 408.4 (A)
-
Question 10 of 18
10. Question
1 pointsMinimum space between the bottom of the enclosures and non-insulated busbars entering the switchboards or floor-standing panel-boards is:
Correct
Please Refer: NEC Code Table 408.5
Incorrect
Please Refer: NEC Code Table 408.5
-
Question 11 of 18
11. Question
1 pointsIn switchboards or panel-boards unused openings for circuit breakers and switches shall be always closed using identical enclosures
Correct
Please Refer: NEC Code 408.7
Incorrect
Please Refer: NEC Code 408.7
-
Question 12 of 18
12. Question
1 pointsOver-current protective device shall be located at the supply side of the panel board
Correct
Please Refer: NEC Code 408.36
Incorrect
Please Refer: NEC Code 408.36
-
Question 13 of 18
13. Question
1 pointsRelays and Meters located on the swithboards shall always be grounded:
Correct
Please Refer: NEC Code 408.22
Incorrect
Please Refer: NEC Code 408.22
-
Question 14 of 18
14. Question
1 points___ is the minimum space required to be provided between the top of the switchboard (not totally enclosed) and any combustible ceiling
Correct
Please Refer: NEC Code 408.18
Incorrect
Please Refer: NEC Code 408.18
-
Question 15 of 18
15. Question
1 pointsPanel-boards equipped with snap switches of rating 30 amps or less shall be provided with over-current protection of not more than _____
Correct
Please Refer: NEC Code 408.36 (A)
Incorrect
Please Refer: NEC Code 408.36 (A)
-
Question 16 of 18
16. Question
1 pointsWhen a transformer supplies power to panel-board, the over-current protection shall be located at __ side of the transformer
Correct
Please Refer: NEC Code 408.36 (B)
Incorrect
Please Refer: NEC Code 408.36 (B)
-
Question 17 of 18
17. Question
1 pointsA delta breaker shall not be installed in panel-board
Correct
Please Refer: NEC Code 408.36 (C)
Incorrect
Please Refer: NEC Code 408.36 (C)
-
Question 18 of 18
18. Question
1 pointsFuses installed as part of service equipment in panel-boards shall be permitted on the load side of the service switch
Correct
Please Refer: NEC Code 408.39
Incorrect
Please Refer: NEC Code 408.39