NEC 410 Luminaires Lamp-holders and Lamps Quiz Questions
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading...
You must sign in or sign up to start the quiz.
You have to finish following quiz, to start this quiz:
Results
0 of 27 questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 points, (0)
Average score |
|
Your score |
|
Categories
- Not categorized 0%
-
Congrats, You Passed the Test
-
Sorry, You did not Pass
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- 16
- 17
- 18
- 19
- 20
- 21
- 22
- 23
- 24
- 25
- 26
- 27
- Answered
- Review
-
Question 1 of 27
1. Question
1 pointsNo parts of cord connected luminaries shall be located within a zone measured not less than ____ feet horizontally from the top of the bathtub rim
Correct
Please Refer: NEC Code 410.10 (D)
Incorrect
Please Refer: NEC Code 410.10 (D)
-
Question 2 of 27
2. Question
1 pointsSecurely fastened luminaries installed in or on the ceiling of the wall are permitted to be located in the bathtub or shower area:
Correct
Please Refer: NEC Code 410.10 (D)
Incorrect
Please Refer: NEC Code 410.10 (D)
-
Question 3 of 27
3. Question
1 pointsWhich of the following is/are examples of damp locations:
- Some Cold Storage warehouses
- Roofed open porches and carports
Correct
Incorrect
-
Question 4 of 27
4. Question
1 pointsCleat-type lampholders located at least ____ feet above the floor shall be permitted to have exposed terminals
Correct
Please Note: NEC Code 410.5
Incorrect
Please Note: NEC Code 410.5
-
Question 5 of 27
5. Question
1 pointsLuminaries shall be installed, equipped with shades and guards such that combustable material is not subjected to temperatures in excess of ______
Correct
Please Refer: NEC Code 410.11
Incorrect
Please Refer: NEC Code 410.11
-
Question 6 of 27
6. Question
1 pointsThe minimum clearance between recessed fluorescent luminaries installed in wall or ceiling installed in clothes closets and the nearest point of the closet storage space is ______
Correct
Please Note: NEC Code 410.16 (C)
Incorrect
Please Note: NEC Code 410.16 (C)
-
Question 7 of 27
7. Question
1 pointsLuminaries must be designed and installed not only to protect overheating of the conductors but also to prevent the overheating of adjacent combustible wall or ceiling finishes
Correct
Please Refer: NEC Code 410.23
Incorrect
Please Refer: NEC Code 410.23
-
Question 8 of 27
8. Question
1 pointsA Hinged base Pole shall have a handhole if the height of the pole is less than 20 feet
Correct
Please Refer: NEC Code 410.30 (B) Exp-2
Incorrect
Please Refer: NEC Code 410.30 (B) Exp-2
-
Question 9 of 27
9. Question
1 pointsOutdoor luminaries and associated equipment shall be permitted to be supported by trees
Correct
Please Refer: NEC Code 410.36 (G)
Incorrect
Please Refer: NEC Code 410.36 (G)
-
Question 10 of 27
10. Question
1 pointsIt is permitted to be provided with GFCI protection for personnel where luminaires are supplied by a circuit that does not have a equipment grounding conductors:
Correct
Please Refer: NEC Code 410.44
Incorrect
Please Refer: NEC Code 410.44
-
Question 11 of 27
11. Question
1 pointsLamp tie wires, mounting screws, and decorative bands on glass spaced atleast _____from lamp terminals shall not be required to be grounded:
Correct
Please refer: NEC Code 410.42
Incorrect
Please refer: NEC Code 410.42
-
Question 12 of 27
12. Question
1 pointsPendent Conductors for Incandescent Filament Lamps which are larger than ___ feet shall be twisted together where not cabled in a listed assembly:
Correct
Please Refer: NEC Code 410.54 (C)
Incorrect
Please Refer: NEC Code 410.54 (C)
-
Question 13 of 27
13. Question
1 pointsPendent Conductors for Incandescent Filament Lamps shall not be smaller than _____ for mogul-base or medium base screw shell lampholders
Correct
Please Refer: NEC Code 410.54 (B)
Incorrect
Please Refer: NEC Code 410.54 (B)
-
Question 14 of 27
14. Question
1 pointsStranded Conductors shall not be used for wiring of luminaire chains and another movable or flexible parts
Correct
Please Refer: NEC Code 410.56 (E)
Incorrect
Please Refer: NEC Code 410.56 (E)
-
Question 15 of 27
15. Question
1 pointsReceptacles and attachment plugs shall have lower ampere rating not less than _____ of the luminaire full load current:
Correct
Please Refer: NEC Code 410.62 (C) (2)
Incorrect
Please Refer: NEC Code 410.62 (C) (2)
-
Question 16 of 27
16. Question
1 pointsWhich of the following is correct:
- Statement: Non metallic lampholders does not require bushings
- Reason: As the material and the design afford equivalent protection
Correct
Please Refer: NEC Code 410.62 (A)
Incorrect
Please Refer: NEC Code 410.62 (A)
-
Question 17 of 27
17. Question
1 pointsIn Cord Connected Installation for Electric Discharge and LED luminaires, the supply cord is not permitted to penetrate a suspended ceiling
Correct
Please Refer: NEC Code 410.62 (C) (2) (a)
Incorrect
Please Refer: NEC Code 410.62 (C) (2) (a)
-
Question 18 of 27
18. Question
1 points______ number of individual showcases can be coupled together by a flexible cord that can be connected to permanently installed receptacles
Correct
Please Refer: NEC Code 410.59
Incorrect
Please Refer: NEC Code 410.59
-
Question 19 of 27
19. Question
1 pointsElectrical rating of the Luminaire shall include only voltage and frequency rating
Correct
Please Refer: NEC Code 410.70
Incorrect
Please Refer: NEC Code 410.70
-
Question 20 of 27
20. Question
1 pointsLED Driver is common industrial term referring to the power supply for the LED:
Correct
Incorrect
-
Question 21 of 27
21. Question
1 pointsWhich of the following Statement related to Portable Handlamps is/are Correct:
- Shall be always Grounded
- Shall be supplied through Isolation Transformer
- Voltage should not be more than 50 Volts
Correct
Please Refer: NEC Code 410.82 (B) (5)
Incorrect
Please Refer: NEC Code 410.82 (B) (5)
-
Question 22 of 27
22. Question
1 pointsWhen a 2-wire circuit is derived from two ungrounded conductors of a multiwire circuit and is used with switched lampholders, the switching device required is to be:
Correct
Please Refer: NEC Code 410.93
Incorrect
Please Refer: NEC Code 410.93
-
Question 23 of 27
23. Question
1 pointsLampholders near Combustible Materials shall be constructed, installed or equipped with shades or guards such that the combustible material is not subjected to exceed the temperature of about ____
Correct
Please Refer: NEC Code 410.97
Incorrect
Please Refer: NEC Code 410.97
-
Question 24 of 27
24. Question
1 pointsIncandescent Lamp for general use on Mogul Base Lighting Branch Circuit Shall not be rated over _____
Correct
Please Refer: NEC Code 410.103
Incorrect
Please Refer: NEC Code 410.103
-
Question 25 of 27
25. Question
1 pointsThermal Protection shall be required in a recessed luminaire installed in poured concrete
Correct
Please Refer: NEC Code 410.115 (C) Exp-1
Incorrect
Please Refer: NEC Code 410.115 (C) Exp-1
-
Question 26 of 27
26. Question
1 pointsType IC recessed luminaires shall not be permitted to be in contact with combustible materials at recessed parts and points of support
Correct
Please Refer: NEC Code 410.116 (2)
Incorrect
Please Refer: NEC Code 410.116 (2)
-
Question 27 of 27
27. Question
1 pointsThermal Insulation shall not be installed above a recessed or within _____ inches of the recessed luminaire enclosure
Correct
Please Refer: NEC Code 410.116 (B)
Incorrect
Please Refer: NEC Code 410.116 (B)