NEC 760: Fire Alarm Systems Quiz Questions
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading...
You must sign in or sign up to start the quiz.
You have to finish following quiz, to start this quiz:
Results
0 of 10 questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 points, (0)
Average score |
|
Your score |
|
Categories
- Not categorized 0%
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- Answered
- Review
-
Question 1 of 10
1. Question
1 pointsThe branch circuit supplying the fire alarm equipment(s) shall be supplied through ground-fault
circuit interrupters or arc-fault circuit-interrupters.Correct
Please Refer: NEC Code 760.41 (B)
Incorrect
Please Refer: NEC Code 760.41 (B)
-
Question 2 of 10
2. Question
1 pointsThe branch-circuit overcurrent protection supplying the fire alarm system shall not exceed ___ amperes
Correct
Please Refer: NEC Code 760.127
Incorrect
Please Refer: NEC Code 760.127
-
Question 3 of 10
3. Question
1 pointsFire alarm system cabbles exposed within 7 ft (2.1 m) of the floor, the cable shall be securely fastened at intervals not over ___:
Correct
Please Refer: NEC Code 760.130(B)(1)
Incorrect
Please Refer: NEC Code 760.130(B)(1)
-
Question 4 of 10
4. Question
1 pointsThe branch circuit supplying the fire alarm equipment(s) shall supply no other loads.
Correct
Please Refer: NEC Code 760.41(B)
Incorrect
Please Refer: NEC Code 760.41(B)
-
Question 5 of 10
5. Question
1 pointsThe fire alarm circuit disconnect shall be permitted to be secured in the __ position.
Correct
Please refer: NEC Code 760.41(A)
Incorrect
Please refer: NEC Code 760.41(A)
-
Question 6 of 10
6. Question
1 pointsOvercurrent protection for NPLFA circuit shall not exceed _____ amperes for 16 AWG conductors.
Correct
Please Refer: NEC Code 760.43
Incorrect
Please Refer: NEC Code 760.43
-
Question 7 of 10
7. Question
1 pointsCables shall be installed in metal raceways or rigid nonmetallic conduit where passing through a floor or wall to a height of ___ above the floor:
Correct
Please Refer: NEC Code 760.130(B)(2)
Incorrect
Please Refer: NEC Code 760.130(B)(2)
-
Question 8 of 10
8. Question
1 pointsCable and conductors of two or more power-limited fire alarm circuits shall be permitted
within the same cable, enclosure, cable tray, or racewayCorrect
Please Refer: NEC Code760.139(A)
Incorrect
Please Refer: NEC Code760.139(A)
-
Question 9 of 10
9. Question
1 pointsCables shall not be supported by taping, strapping, or attaching by any means to any electrical
conduits, or other racewaysCorrect
Please Refer: NEC Code 760.143
Incorrect
Please Refer: NEC Code 760.143
-
Question 10 of 10
10. Question
1 pointsLow-power network powered broadband communications circuits shall not be permitted
in the same enclosure, cable tray, or raceway with PLFA cables.Correct
Please Refer: NEC Code 760.139(C)
Incorrect
Please Refer: NEC Code 760.139(C)