Quiz-summary
0 of 15 questions completed
Questions:
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
Information
NEC Code 250: Grounding and Bonding Quiz Questions
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading...
You must sign in or sign up to start the quiz.
You have to finish following quiz, to start this quiz:
Results
0 of 15 questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 points, (0)
Average score |
|
Your score |
|
Categories
- Not categorized 0%
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- Answered
- Review
-
Question 1 of 15
1. Question
1 pointsElectrical system grounding will stabilize the voltage to earth during normal operation:
Correct
Please Refer: NEC Code 250.4(A)(1)
Incorrect
Please Refer: NEC Code 250.4(A)(1)
-
Question 2 of 15
2. Question
1 pointsElectrical system grounding that is connected to earth will limit the voltage imposed by which of the following:
Correct
Incorrect
-
Question 3 of 15
3. Question
1 pointsIn case of multiple grounding connections in order to reduce the objectionable current all grounding connections shall be disconnected:
Correct
Please Refer: NEC Code 250.6(B)(1)
Incorrect
Please Refer: NEC Code 250.6(B)(1)
-
Question 4 of 15
4. Question
1 pointsIn case of AC system 3-phase, 4 wire wye connected system having voltage range between 50V and 1000V which of the following is grounded:
Correct
Please Refer: NEC Code 250.24(B)(2)
Incorrect
Please Refer: NEC Code 250.24(B)(2)
-
Question 5 of 15
5. Question
1 pointsIn case of 3-wire 4 wire delta connected AC system having voltage range between 50V and 1000V, mid point of one phase winding is used as a grounding conductor:
Correct
Please Refer: NEC Code 250.24(B)(3)
Incorrect
Please Refer: NEC Code 250.24(B)(3)
-
Question 6 of 15
6. Question
1 pointsTransformer secondary circuit having voltage levels less than 50V shall not be grounded if the supply side of the transformer is grounded:
Correct
Please Refer: NEC Code 250.20(A)(2)
Incorrect
Please Refer: NEC Code 250.20(A)(2)
-
Question 7 of 15
7. Question
1 pointsWhere the transformer supplying the service is located outside the building, at least ____
additional grounding connection shall be made from the grounded service conductor to a grounding electrode:Correct
Please Refer: NEC Code 250.24(A)(2)
Incorrect
Please Refer: NEC Code 250.24(A)(2)
-
Question 8 of 15
8. Question
1 pointsThe connection of grounded service conductor to the grounding electrode conductor is permitted in which of the location:
Correct
Please Refer: NEC Code 250.24(A)(1)
Incorrect
Please Refer: NEC Code 250.24(A)(1)
-
Question 9 of 15
9. Question
1 pointsMain bonding jumpers and system bonding jumpers shall not be made of copper:
Correct
Please Refer: NEC Code 240.28(A)
Incorrect
Please Refer: NEC Code 240.28(A)
-
Question 10 of 15
10. Question
1 pointsIn case of the outdoor transformer supplying the service, the additional grounding electrode conductor connection shall be made on high impedance grounded neutral system:
Correct
Please Refer: NEC Code 250.24(A)(2) Exp-1
Incorrect
Please Refer: NEC Code 250.24(A)(2) Exp-1
-
Question 11 of 15
11. Question
1 pointsWhich of the following circuits cannot be grounded: (multiple answer question)
Correct
Incorrect
-
Question 12 of 15
12. Question
1 pointsAC Electrical systems having voltage rating between 50V and 1000V used exclusively to supply industrial electric furnaces for melting, refining, and tempering shall not be grounded:
Correct
Please Refer: NEC Code 250.21(A)(1)
Incorrect
Please Refer: NEC Code 250.21(A)(1)
-
Question 13 of 15
13. Question
1 pointsMachine screws and thread-forming machine screws shall not be used to connect grounding and bonding conductors.
Correct
Please Refer: NEC Code 250.8(A)
Incorrect
Please Refer: NEC Code 250.8(A)
-
Question 14 of 15
14. Question
1 pointsThe size of the neutral conductor is determined by which of the following:
Correct
Incorrect
-
Question 15 of 15
15. Question
1 pointsIn case of high impedance grounding systems, grounding system conductor shall not be smaller than ___ copper and ____ aluminum:
Correct
Please Refer: NEC Code: 250.36(B)
Incorrect
Please Refer: NEC Code: 250.36(B)