NEC Code 480: Storage Batteries Quiz Questions Answers
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading...
You must sign in or sign up to start the quiz.
You have to finish following quiz, to start this quiz:
Results
0 of 10 questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 points, (0)
Average score |
|
Your score |
|
Categories
- Not categorized 0%
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- Answered
- Review
-
Question 1 of 10
1. Question
1 points___ are rigid frames designed to support cells or trays
Correct
Please Refer: NEC Code 480.8
Incorrect
Please Refer: NEC Code 480.8
-
Question 2 of 10
2. Question
1 pointsWhich of the following is a storage battery:
Correct
Incorrect
-
Question 3 of 10
3. Question
1 pointsIn Lead acid batteries, ____gas is liberated at positive plate and ____ gas is liberated at negative plate respectively:
Correct
Incorrect
-
Question 4 of 10
4. Question
1 pointsOvercurrent protection shall not be required to be provided for conductors from a battery rated less than __ volts if battery is provided for starting of prime mover:
Correct
Please Refer: NEC Code 480.4
Incorrect
Please Refer: NEC Code 480.4
-
Question 5 of 10
5. Question
1 pointsSealed Cell or Battery shall not be provided by pressure relief venting
Correct
Please Refer: NEC Code 480.2
Incorrect
Please Refer: NEC Code 480.2
-
Question 6 of 10
6. Question
1 pointsWorking clearance shall be measured from the ___ of the battery rack:
Correct
Please Refer: NEC Code 480.9(C)
Incorrect
Please Refer: NEC Code 480.9(C)
-
Question 7 of 10
7. Question
1 pointsEach vented cell must be equipped with flame arrester:
Correct
Please Refer: NEC Code 480.10(A)
Incorrect
Please Refer: NEC Code 480.10(A)
-
Question 8 of 10
8. Question
1 pointsA minimum separation between two live parts of opposite polarities of plates shall be ___ for battery voltage not exceeding 600V
Correct
Please Refer: NEC Code 480.7
Incorrect
Please Refer: NEC Code 480.7
-
Question 9 of 10
9. Question
1 pointsSealed cells operating not over 250V constructed of non conductive heat restrained material shall not requiring additional insulation support:
Correct
Please Refer: NEC Code 480.6
Incorrect
Please Refer: NEC Code 480.6
-
Question 10 of 10
10. Question
1 pointsA disconnecting means shall be provided for all ungrounded conductors derived from stationary battery system over ____ volts:
Correct
Please Refer: NEC Code 480.5
Incorrect
Please Refer: NEC Code 480.5