One Family Dwellings NEC Code Quiz Questions:
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading...
You must sign in or sign up to start the quiz.
You have to finish following quiz, to start this quiz:
Results
0 of 15 questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 points, (0)
Average score |
|
Your score |
|
Categories
- Not categorized 0%
-
Congrats, You Passed the Test
-
Sorry, You did not Pass
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- Answered
- Review
-
Question 1 of 15
1. Question
1 pointsBranch Circuit Conductors shall have an ampacity not less than maximum load served:
Correct
Please Refer: NEC Code – 210.19 (A) (1)
Incorrect
Please Refer: NEC Code – 210.19 (A) (1)
-
Question 2 of 15
2. Question
1 pointsGeneral Purpose Branch Circuit overcurrent protection shall not exceed ____ for 14 AWG Copper wire:
Correct
Please Refer: NEC Code – 240.4(D)
Incorrect
Please Refer: NEC Code – 240.4(D)
-
Question 3 of 15
3. Question
1 pointsReceptacles installed on 20 Amp Circuit can have an ampere rating of:
Correct
Please Refer: NEC Code – Table 210.21(B)(3)
Incorrect
Please Refer: NEC Code – Table 210.21(B)(3)
-
Question 4 of 15
4. Question
1 pointsA 20 Ampere can be installed on 15 Ampere Circuit:
Correct
Incorrect
-
Question 5 of 15
5. Question
1 pointsReceptacles shall be installed so that no point measured horizontally along the floor line in any wall space is more than ___ from the receptacle outlet.
Correct
Please Refer: NEC Code – 210.52(A)1
Incorrect
Please Refer: NEC Code – 210.52(A)1
-
Question 6 of 15
6. Question
1 pointsThe maximum horizontal distance between two Receptacles in a room is:
Correct
Please Refer: NEC Code – 210.52(A)1
Incorrect
Please Refer: NEC Code – 210.52(A)1
-
Question 7 of 15
7. Question
1 pointsWall space determines the minimum number of receptacles:
Correct
Please Refer: NEC Code – 210.52(A)
Incorrect
Please Refer: NEC Code – 210.52(A)
-
Question 8 of 15
8. Question
1 pointsA receptacle is required for any wall space ___ or more in width unbroken along the floor line by doorways, fireplaces and similar openings
Correct
Please Refer: NEC Code – 210.52(A)(2)(1)
Incorrect
Please Refer: NEC Code – 210.52(A)(2)(1)
-
Question 9 of 15
9. Question
1 pointsSliding panels in exterior walls are counted as wall space for measuring the distance between the receptacles.
Correct
Please Refer: NEC Code – 210.52(A)(2)(2)
Incorrect
Please Refer: NEC Code – 210.52(A)(2)(2)
-
Question 10 of 15
10. Question
1 pointsReceptacles located more than _____ above the floor are permitted, they are not counted as required receptacles.
Correct
Please Refer: NEC Code – 210.52
Incorrect
Please Refer: NEC Code – 210.52
-
Question 11 of 15
11. Question
1 pointsThe space afforded by fixed room dividers, such as railings or freestanding bar type counters shall not be counted as wall space:
Correct
Please Refer: NEC Code 210.52(A)(2)(3)
Incorrect
Please Refer: NEC Code 210.52(A)(2)(3)
-
Question 12 of 15
12. Question
1 pointsLuminaries and appliances with built in receptacles can be count as required number of receptacles.
Correct
Please Refer: NEC Code 210.52
Incorrect
Please Refer: NEC Code 210.52
-
Question 13 of 15
13. Question
1 pointsVegetation can be used to support overhead conductor spans for supporting temporary wiring:
Correct
Please Refer: NEC Code 225.26
Incorrect
Please Refer: NEC Code 225.26
-
Question 14 of 15
14. Question
1 pointsService heads must be located above the point where service drop conductors are attached to the building or other structures
Correct
Please Refer: NEC Code 230.54(C)
Incorrect
Please Refer: NEC Code 230.54(C)
-
Question 15 of 15
15. Question
1 pointsReceptacles not serving kitchen counter tops shall require GFCI Protection:
Correct
Incorrect