Information
One Family Dwellings NEC Quiz Questions Answers 4
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading...
You must sign in or sign up to start the quiz.
You have to finish following quiz, to start this quiz:
Results
0 of 12 questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 points, (0)
Average score |
|
Your score |
|
Categories
- Not categorized 0%
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- Answered
- Review
-
Question 1 of 12
1. Question
1 pointsThe vertical clearance above the roof level must be maintained for a distance of atleast _____ from all edges of the roof:
Correct
Please Refer: NEC Code 230.24(A)
Incorrect
Please Refer: NEC Code 230.24(A)
-
Question 2 of 12
2. Question
1 pointsThe measurement of horizontal overhead service conductors above hanging portions of the roof shall not exceed ____:
Correct
Incorrect
-
Question 3 of 12
3. Question
1 pointsOverhead service conductors above the roof with a slope less than 4 inches in 12 inches shall have a minimum clearance of ____:
Correct
Please Refer: NEC Code 230.24(A)
Incorrect
Please Refer: NEC Code 230.24(A)
-
Question 4 of 12
4. Question
1 pointsThe frontal workspace width of electric equipment must be greater of the width of the equipment or ___:
Correct
Please Refer: NEC Code 110.26(A)(2)
Incorrect
Please Refer: NEC Code 110.26(A)(2)
-
Question 5 of 12
5. Question
1 pointsFor vertically operated circuit breaker, the UP position of the handle must be the OFF position:
Correct
Please Refer: NEC Code 240.81 and 404.7
Incorrect
Please Refer: NEC Code 240.81 and 404.7
-
Question 6 of 12
6. Question
1 pointsIn damp and wet location, a minimum of ____ air space between the enclosure and the wall or other supporting surface is required:
Correct
Please Refer: NEC Code 312.2
Incorrect
Please Refer: NEC Code 312.2
-
Question 7 of 12
7. Question
1 pointsA one family dwelling service disconnecting means must have a minimum rating of ____:
Correct
Please Refer: NEC Code 230.79(C)
Incorrect
Please Refer: NEC Code 230.79(C)
-
Question 8 of 12
8. Question
1 pointsPanelboards equipped with a snap switches rated at 30A or less shall have overcurrent protection of _____ or less:
Correct
Please Refer: NEC Code 408.36(A)
Incorrect
Please Refer: NEC Code 408.36(A)
-
Question 9 of 12
9. Question
1 pointsType S adopters must fit Edison-base fuseholders:
Correct
Please Refer: NEC Code 240.54(A)
Incorrect
Please Refer: NEC Code 240.54(A)
-
Question 10 of 12
10. Question
1 pointsAt least one structural metal member must be in direct contact with the earth for ___ or more, with or without concrete encasement:
Correct
Incorrect
-
Question 11 of 12
11. Question
1 pointsA 3 ft clearance of service and outside wiring clearances criteria is not applicable if the conductor run above the top level of the window:
Correct
Please Refer: NEC Code 230.9(D)(1) Exp
Incorrect
Please Refer: NEC Code 230.9(D)(1) Exp
-
Question 12 of 12
12. Question
1 pointsConductors of different potentials must be brought out of service heads through separately bushed openings:
Correct
Please Refer: NEC Code 230.54(E)
Incorrect
Please Refer: NEC Code 230.54(E)